Home > Bottom in up out P8 Variable area float flow meter
Bottom in up out P8 Variable area float flow meter
- Product No.:P8FB
Bottom in up out P8 Variable area float flow meter | |||||
Feature | |||||
1:All metal construction, strong and stable | |||||
2:Short stroke, compact structure. | |||||
3:Low pressure loss design. | |||||
4:New style magnetic coupling structure ensures that the signal transmission is more stable. | |||||
5:Magnetic filter can be added as customer requirements | |||||
6:Thermal insulation or tracing heat jacket. | |||||
7:Used in the gas and liquid measurement in all industries. The measurment parts can adopt different materials to be suitable for different medias. | |||||
8:Suitable for harsh environment and seriously corrosion media. Having good heat resistance and pressure resistance. | |||||
9:Intelligent dual-line LCD display, on site instant/ umulative flow display and back light as options. | |||||
10:Two-wire system, battery, alternating current can be choosed to supply the power. | |||||
Type | R56 | ||||
Medium | Liquids, gases, vapors | ||||
Flow Range | Water :20℃ | (10-300000)L/h ,Special orderon request: | |||
Air :0.1013MPa, 20℃ | (0.7-3000)Nm3/h, Special order on request: | ||||
The turn-down ratio | 10:01 | ||||
Accuracy class | Mechanical indicator | 1.0, 1.5, 2.0, 2.5 | |||
Mechanical indicator with LCD(battery powered, service life: 2 years) | 1.0, 1.5, 2.0, 2.5 | ||||
Mechanical indicator with two-wire signal output (4-20)mA/hartcommunication protocol | 1.0, 1.5, 2.0, 2.5 | ||||
Medium temperature | Machinery indicator with LCD(battery powered, service life: 2 years) | -80℃~+300℃(PTFE:0~80℃) | |||
High temperature 400℃ | |||||
Mechanical indicator(battery powered, service life: 2 years) | -40℃~+120℃(PTFE:0~80℃) | ||||
High temperature 400℃ | |||||
Mechanical indicator with two-wire signal output (4-20)mA/hartcommunication protocol | -40℃~+120℃(PTFE:0~80℃) | ||||
Hightemperature400℃ | |||||
Ambient temperature | Mechanical indicator | -40℃~+120℃ | |||
Mechanical indicator with LCD(battery powered, service life: 2 years) | -20℃~+60℃ | ||||
Mechanical indicator with two-wire signal output (4-20)mA/hartcommunication | -20℃~+60℃ | ||||
Viscosity of fluid | DN15: F15.00~F15.03η<5 mPa.s, F15.04~15.30 η<30 mPa.s; DN25:η<250 mPa.s; DN50~250: η<300 mPa.s | ||||
Nominal pressure | DN15~DN50 | 4.0MPa(Max DN15: 42MPa, DN25: 42MPa, DN50: 32MPa) | |||
DN80~DN250 | 1.6MPa(Max DN80: 10MPa, DN100: 6.4MPa, DN125: 4.0MPa, | ||||
DN150: 4.0MPa, DN200: 2.5MPa, DN250: 2.5Mpa) | |||||
Process connection | Flange connection, Standard:DIN2501, ANSI, JIS(selectChinese standard freely, priority select DIN) | ||||
Hygieneclamp, screw jointare selected in the order | |||||
Electrical connection | M20×1.5 1/2"G 1/2"NPT 3/4"G 3/4"NPT | ||||
Installation | Vertical mounting(bottom in up out and up in bottom out, Horizontal mounting(left in rightout and right in left out) | ||||
bottom in side out, side in side out | |||||
Straight unimpeded inlet run | ≥5D | ||||
Straight unimpeded outlet run | ≥250mm | ||||
Degree of protection | IP67(Others need specify in the order) | ||||
Exmarking | EExia II CT5 | ||||
EEx d II CT6 | |||||
Exelectricaldata | Ui=28V Ii=93mA Pi= 0.65W Ci≤ 5nF Li =0mH | ||||
Safety barrier data | Uo≤ 28V Io≤ 93mA Po≤ 0.65W Co≥ Ci+Cc Lo≥ Li+Lc | ||||
Carried Standard | JB/T 6844-93 |
Previous Product:Bottom in up out P10 Variable area float flow meter
Next Product:Thread Connection P10 Variable area float flow meter